9.1.3 Output control & configuration
Cmd Description Syntax Comments
1000 Set DO cmd,m,n m:0-8, n:1-4 (base)
or 1-2 (ext)
1001 Reset DO cmd,m,n m:0-8, n:1-4 (base)
or 1-2 (ext)
1010 Pulse DO cmd,m,n,s m:0-8, n:1-4 (base)
or 1-2 (ext), s:1-79200
seconds
1020 Set DO After
Delay
cmd,m,n,h,mn m:0-8, n:1-4 (base)
or 1-2 (ext),
h:0-21 hours,
mn:0-59 minutes
1021 Reset DO
After Delay
cmd,m,n,h,mn m:0-8, n:1-4 (base)
or 1-2 (ext),
h:0-21 hours,
mn:0-59 minutes
1030 Attach DO to
Time
Schedule
cmd,m,n,id m:0-8, n:1-4 (base)
or 1-2 (ext), id:1-10
1040 Set DO as
Multivibrator
cmd,m,n,mon,
moff
m:0-8, n:1-4 (base)
or 1-2 (ext),
mon:1-1320 minutes,
moff:1-1320 minutes
1050 Set DO
Name
cmd,m,n,s m:0-8, n:1-4 (base)
or 1-2 (ext), s:0-15